DD 1050

The DD 1050 can replace a traditional PC with a locked-down, industrialized solution meant to withstand harsh environments. The DD 1050 is a perfect solution for walking a user through a series of steps and printing weight tickets or saving and transferring the data to central server. The power of the system lies in its ability to help eliminate user error as well as make your input process more user-friendly through its 10.4" touchscreen interface.

Tech Specs

  • 500 MHz processor
  • 128 MB ram
  • 128 MB flash memory
  • 10.4" color TFT display with touch screen
  • 10/100 BaseT Ethernet onboard
  • 2 x I/O 24V ac/dc
  • 1 memory card expansion slot (SD, Compact Flash)
  • 3 expansion slots (for weighing machines, serial port, I/O, field buses, etc.)
  • Power supply: 110-230 VAC
  • NTEP Approval for up to 10,000 divisions
    • Multidivision and Multirange versions

Options

Serial Output Card

  • A card that makes it possible to manage two extra serial outputs in addition to the two already provided
    • RS232, RS422 and RS485 formats
    • Programmable Baud Rate

Input/Output Card

  • Each card provides up to 8 inputs and 12 outputs in addition to those already provided with the standard terminal
  • Input: optical isolation, Vmax 5 VDC, for clean contacts or NPN transistors
  • Output: Optomos, Vmax 24 VAC/DC, Imax 190 mA

Profibus Connection Card

  • Profibus DP functionality
  • Galvanic isolation
  • Data rate from 9.6 kbit/s to 12 Mbit/s

Wireless Communication Device

  • 802.11b WiFi data transmission device
  • UMTS/GPRS/GSM MODEM for remote wireless management

User Identification Device

  • Optic, magnetic or radio frequency devices

Digital/Analog Card

  • Optional multifunctional card, particular useful for process control
    • 1 x 0-10V / 4-20 mA analog output
    • 4 x Fmax 2kHz pulse counter inputs
    • 1 x 0-10V / 4-20 mA analog inputs

Weighing Machine Interface Card

Analog
  • Internal resolution up to one million points
  • Conversion speed up to 100 reading per second
  • 10 VDC load cell power supply
  • Configurable digital filters
Digital
  • RS485 interface with dedicated protocol
  • Digital load cell diagnostic management system (conversion, power, temperature, etc.)
  • Software correction for eccentric loads